K-2005-SALT

Complete™ kit for Chlorine/Bromine, pH, Alkalinity, Hardness, CYA, Salt (DPD) (.75 oz bottles)

UPC Barcode:
840036031285

$147.57

Analyte System Method/Chemistry Standard/Equivalance or Description Comparator Cell
Alkalinity, Total Drop test Blended indicator 1 drop = 10 ppm total alkalinity as CaCO₃ 9056 NA
Hardness, Calcium Drop test EDTA titration (includes inhibitors to prevent metal interference) 1 drop = 10 ppm calcium hardness as CaCO₃ 9056 NA
Chlorine, Free & Total 2000 Series comparator DPD 1, 2, 3, 5, 7.5, 10 ppm chlorine (Cl₂) 9056 NA
pH w/ acid/base demand 2000 Series comparator Phenol red 7.0, 7.2, 7.4, 7.6, 7.8, 8.0 9056 NA
Bromine, Total 2000 Series comparator DPD 2, 4, 6, 10, 15, 20 ppm bromine (Br₂) 9056 NA
Chloride (Sodium Chloride) Drop test Argentometric (.75 oz) 1 drop = 200 ppm NaCl NA 9198
Cyanuric Acid Visual determination Turbidimetric 30, 40, 50, 60, 70, 80, 90, 100 ppm CYA 9056 NA
Test Parameter Description
Metal ions may cause interference; to prevent, add titrant containing EDTA to sample before buffer and indicator, then test as normal making sure to count drops of titrant added initially in total required to reach endpoint. If interference still occurs, dilute sample with DI water as necessary and retest. Calcium, Magnesium, Total Hardness
Orthophosphate at concentrations greater than 25 ppm will precipitate as silver phosphate to cause positive interference. This can be prevented by diluting orthophosphate concentrations below 25 ppm with DI water. Bromide, iodide, and cyanide at all levels titrate as equivalent chloride concentrations. Sulfide, thiosulfate, and sulfite interfere but can be removed by treatment with hydrogen peroxide. Quats may interfere; to prevent add 10 drops of R-0884. Chloride
Chlorine levels > approx. 10 ppm may bleach out indicator; to prevent, dilute sample with DI water as necessary and retest. Chlorine
Other halogens and oxidized manganese may cause positive interference. Chlorine
Iron > 10 ppm may cause negative interference. pH
Sanitizer levels > approx. 10 ppm may cause a blue-purple color resulting in false high readings. Wait for sanitizer level to decrease to normal levels and retest to assure an accurate reading. pH
High halogen level may change indicator reaction from green/red to blue/yellow; to prevent, add thiosulfate prior to testing. Total Alkalinity

TEST STRIP SHELF LIFE

As with all perishables, test strips are sensitive to environmental influences and will last longer under controlled conditions.

To this end, we recommend:

  • Storing test strips at a consistent temperature in the range of 36°–85°F (2°–29°C); storing test strips in a refrigerator can prolong the shelf life, but the bottle must be warmed to room temperature before opening to avoid condensation.   
  • Keeping them out of prolonged direct sunlight.
  • Segregating test strips from containers of treatment chemicals.
  • Replacing bottle lids immediately to reduce exposure to air and humidity.

Taylor formulates its test strips to remain effective for two years, the only exception being Salt test strips which last one year. As a general precaution, replace all test strips more than one year old, or at the beginning of a new testing season.